Jump to text
On this page
Copy and source
Published source confirmed at last check

Source changed 2026-11-23 16:07:44 UTC · snapshot created 2026-11-23 16:09:03 UTC · last check 2026-11-24 02:20:07 UTC

SYSE.10:5.1 - Finish with a Sufficient Direct Result

Suppose the immediate question is whether the completed one-hour trial met its declared 40–45 °C supply-water criterion. Its qualified measurement result gives 41.0–44.0 °C with a conservative 0.2 °C uncertainty bound covering that recorded interval and the named setup. The resulting 40.8–44.2 °C range lies inside the criterion. The engineer can finish: “The temperature criterion was met in this recorded trial under its qualified measurement conditions; use that result in the increment assessment.” This does not assess another operating interval or the cycling criterion. Repeating the measurement or creating a full account adds no required contribution to this direct question.