SYSE.10:5.3 - Change the Premise and Keep the Independent Result

The selected sensor configuration now supplies one update every two seconds after filtering, whereas M17’s qualified configuration used two updates per second. The applicable sensor-age bound becomes 2.0 s. With the unchanged downstream bounds, the available whole-path bound is 2.4 s, which no longer establishes M17’s premise of at most 1.0 s. The model’s old temperature prediction remains a result for its old conditions; it no longer supports the current installed temperature claim. This loss of support does not show that the actual water temperature violates 40–45 °C.

Retain the valid downstream timing results and L4’s independently established restart limit. The conjunction needed for the original favorable recommendation is unresolved because its temperature premise is missing; the passing cycling result cannot compensate. Copied plots of M17 or additional summaries of its traces do not repair that premise. The engineer returns this precise limitation and withholds the favorable assessment for the changed increment. Choosing a supported narrower use, changing the estimator, obtaining a suitable model result or repeating a controller-in-the-loop trial is a separate engineering or inquiry choice. Further Work proceeds only when its continuation has been selected as feasible and worthwhile under C.11 or the specialist Method. Its returned result can then reopen the affected assessment; a missing evidence entry alone is not a reason to commission an experiment.

For a distinct adverse case, consider a qualified installed trace for the changed sensor at an admitted low-ambient load: the calibrated lower limit of a supply-water reading is 45.3 °C. This attainable excursion refutes the claim that temperature always stays within 40–45 °C in that envelope. It says nothing adverse about L4’s restart spacing. If the release deadline instead passes with only the 2.4 s timing bound and an obligatory temperature certificate missing, the board can return the full offer under its evidence rule. For a separately authorized monitored interval, a valid certificate covering that interval and all its service criteria can support a narrower release. Neither the return nor the restricted permission supplies a field measurement.

An AI Agent also proposes fault scenarios and a trace summary. One proposed scenario invents an interface state absent from the configuration. Reject that proposal for this use. The summary can help locate traces, but the assessment relies on their actual results and justified connections. A generated confidence score neither supplies the missing state-age premise nor decides assurance, acceptance or release.