F.11:11.2 - Industrial furnace control
- Method: PID with feed-forward.
- MethodDescription: controller tuning sheet and program description.
- Work: the actual PLC task cycles in the stated interval.
- Outputs: setpoints and valve-duty values produced during those cycles.
- Evidence: temperature observations and their scale and unit basis.
If the IEC task expression and a PROV Activity expression are related for reporting, state that exact F.9 relation and loss. It does not create the Work-to-output or evidence relations.