OPS.11.1:5.6 - Model a continuing service when no case is completed
A facility buys readiness over a four-hour interval: a qualified responder must be able to begin an incident response within ten minutes of an incident’s arrival. The stipulated demand condition permits at most one active incident; the responder remains available for any response owed from that interval. Alerts arrive within one minute. The response method, access and equipment are already qualified.
One arrangement lets the responder perform a records audit while no incident is active. The audit can be left in a resumable state within one minute, and obtaining the response setup takes two more minutes. Even counting those delays consecutively, response can begin within four minutes. The operation can therefore obtain some audit work while preserving the stipulated readiness. A quiet four-hour interval with zero incident completions can still supply the purchased service.
Another proposal assigns the same person to a twelve-minute task that cannot be interrupted. An incident just after that task starts can leave almost fourteen minutes before response begins, including the two-minute setup. Low average incident demand does not make this arrangement satisfy the ten-minute condition. Move that task to other provision, change its interruption method if technically possible, or obtain a different service agreement. OPS.8.2 supplies the fuller release-and-restoration construction.
If demand changes to permit simultaneous incidents requiring separate responders, the single-responder premise fails even though the four-minute return remains attainable. Obtain the required qualified provision or revise the promise. The account keeps availability over an interval, work performed during quiet time and actual incident results distinct; a completed-case count alone cannot express all three.